Winland-electronics EA800-ip Manual de usuario Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 60
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
General Information
D-011-0152 7
Block Diagrams
Figure 2 shows a block diagram of the console interfaces and functions. The EA800 provides eight relays for
indicating when a programmed alarm limit has been exceeded or a warning condition exists. An additional AUX
(Auxiliary) Output relay provides an output signal to an optional audible alarm or strobe that is activated whenever
an alarm condition exists.
Figure 2 EA800 Environmental Alarm System Block Diagram
The EA800 can be made part of a larger security system as shown in Figure 3. In a security system there may be
more than one EA800 installed along with other components such as the Winland EA200 or EA400 multi-zone
environmental alarm systems.
Figure 3 Facility Security System Block Diagram - Example
Sensor 5
Sensor 6
Sensor 7
Sensor 8
Wireless Sensors
Relay 1
Output 1
Output 2
Relay 2
Output 3
Relay 3
Output 4
Relay 4
Output 5
Relay 5
Output 6
Relay 6
Output 7
Relay 7
Output 8
Relay 8
EA800 Console
Aux Output
RF Receiver
Sensor 1
Sensor 2
Sensor 3
Sensor 4
System Control
Relay 9
Relay 1 coil control logic
Relay 2 coil control logic
Relay 3 coil control logic
Relay 4 coil control logic
Relay assignment
and coil control logic
Wired Sensors
Alarm Panel
From other
EA800, EA400, and EA200
Environmental Alarm Systems
Sensor 5
Sensor 6
Sensor 7
Sensor 8
Wireless Sensors
Relay 1
Output 1
Output 2
Relay 2
Output 3
Relay 3
Output 4
Relay 4
Output 5
Relay 5
Output 6
Relay 6
Output 7
Relay 7
Output 8
Relay 8
EA800 Console
Aux Output
RF Receiver
Sensor 1
Sensor 2
Sensor 3
Sensor 4
System Control
Relay 9
Relay 1 coil control logic
Relay 2 coil control logic
Relay 3 coil control logic
Relay 4 coil control logic
Relay assignment
and coil control logic
Sensor 5
Sensor 6
Sensor 7
Sensor 8
Wireless Sensors
Relay 1
Output 1
Output 2
Relay 2
Output 3
Relay 3
Output 4
Relay 4
Output 5
Relay 5
Output 6
Relay 6
Output 7
Relay 7
Output 8
Relay 8
EA800 Console
Aux Output
RF Receiver
Sensor 1
Sensor 2
Sensor 3
Sensor 4
System Control
Relay 9
Relay 1 coil control logic
Relay 2 coil control logic
Relay 3 coil control logic
Relay 4 coil control logic
Relay assignment
and coil control logic
Wired Sensors
Wired Sensors
Vista de pagina 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 59 60